| Reference | Value | Description |
|---|---|---|
| Q0 | Two-pole main disconnect | Disconnect rating, poles, fault rating, and jurisdiction are unresolved. PE bypasses Q0. |
| QF1 | PS1 AC branch protection | Rating and curve require prospective fault current plus the unpublished LRS-350 inrush maximum, duration, waveform, T50, and I-squared-t. Typical inrush alone is insufficient. |
| QF2 | PS2 AC branch protection | Rating and curve require prospective fault current and inrush coordination. |
| QF3 | PS3 AC branch protection | Regional compute-supply branch protection and inlet arrangement are unresolved. |
| QWD1 | HR-V0 3.3 V-to-24 V watchdog coil driver | Transistor or optocoupler circuit, logic polarity, flyback coordination, creepage, and failure response are unresolved. |
| QWDH1 |
| Separate variant driver. Exact circuit and fault response are unresolved. |
| UA1 | ROBOTIS U2D2 - upper bus A | ROBOTIS names pin 2 VDD but does not publish or permit a sense-only path. Pin 2 is omitted pending written manufacturer evidence or a released and tested custom harness. |
|---|
| UB1 | ROBOTIS U2D2 - upper bus B | ROBOTIS names pin 2 VDD but does not publish or permit a sense-only path. Pin 2 is omitted pending written manufacturer evidence or a released and tested custom harness. |
|---|
| UV1 | ROBOTIS U2D2 - V0 TTL interface | ROBOTIS names pin 2 VDD but does not publish or permit a sense-only path. Pin 2 is omitted pending written manufacturer evidence or a released and tested custom harness. |
|---|
| ADC1 | TI ADS131M04 left foot ADC - proposed device | Exact package, pin map, clock, reference, analog power, protection, anti-alias network, and PCB layout are unresolved. |
|---|
| ADC2 | TI ADS131M04 right foot ADC - proposed device | Exact package, pin map, clock, reference, analog power, protection, anti-alias network, and PCB layout are unresolved. |
|---|
| AFE1 | Load-cell excitation, reference, protection, and anti-alias front ends | Excitation voltage, reference, amplifiers if required, filters, protection, calibration injection, and complete PCB circuit are unresolved. |
|---|
| BAT1 | Protected battery pack and conversion - SELECTION REQUIRED | Qualified supplier, chemistry, series count, conversion topology, full-charge and loaded end-of-discharge limits, protected ports, fault current, capacity, enclosure, regeneration, and telemetry are unresolved. |
|---|
| BCU1 | Independent battery sequencing and interlock controller | Controller, independent power, voltage threshold circuit, coil drivers, diagnostics, sequencing logic, and safety-inhibit interface are unresolved. |
|---|
| CHG1 | Battery charger / protected charge interface | Charger compatibility, BMS charge-port topology, communications, isolation, and interlock circuit are unresolved. |
|---|
| DC1 | HR-30 upper-body regulated 12 V converter | Required because the HR-30 source is not assumed to be a verified 12 V rail. Power, efficiency, isolation, transient, and thermal ratings are unresolved. |
|---|
| F0 | HR-V0 main DC fuse | Rating, holder, interrupt rating, conductor protection, and clearing coordination are unresolved. |
|---|
| F1 | Shoulder branch fuse | No fuse value is released. Requires measured current, inrush, cable, connector, ambient, and duty-cycle data. |
|---|
| F2 | Elbow branch fuse | No fuse value is released. Requires measured current, inrush, cable, connector, ambient, and duty-cycle data. |
|---|
| F3 | Gripper branch fuse | No fuse value is released. Requires measured current, inrush, cable, connector, ambient, and duty-cycle data. |
|---|
| FBAT1 | Pack-level fuse at battery | Rating and interrupt capability require pack fault-current data and conductor protection calculation. |
|---|
| FHR0 | HR-30 main actuator fuse | Rating, holder, interrupt capacity, cable protection, and source coordination are unresolved. |
|---|
| FL1 | left hip yaw actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FL2 | left hip roll actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FL3 | left hip pitch actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FL4 | left knee pitch actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FL5 | left ankle pitch actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FL6 | left ankle roll actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FR1 | right hip yaw actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FR2 | right hip roll actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FR3 | right hip pitch actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FR4 | right knee pitch actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FR5 | right ankle pitch actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FR6 | right ankle roll actuator branch fuse | Individual branch protection required by ELEC-003. Rating and holder require measured current, cable, connector, ambient, bundling, and fault data. |
|---|
| FSR1 | PNOZ output-contact protection | Pilz manual p.11 requires output-contact protection. Published maxima are not selections; coordinate the exact protection with coil inrush, conductor, PS2 behavior, and fault current. |
|---|
| FSRH1 | HR-30 PNOZ output-contact protection | Pilz manual p.11 requires output-contact protection. Published maxima are not selections; coordinate the exact protection with coil inrush, conductor, PS2 behavior, and fault current. |
|---|
| FTHR1 | Tether source protection | Rating and protection coordination require source fault-current and cable data. |
|---|
| FU31 | left shoulder pitch branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU32 | left shoulder roll branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU33 | left elbow branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU34 | left wrist branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU35 | left gripper branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU41 | right shoulder pitch branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU42 | right shoulder roll branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU43 | right elbow branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU44 | right wrist branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU45 | right gripper branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU51 | waist yaw branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU52 | head pan branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| FU53 | head tilt branch fuse | Individual fuse and holder rating require the released current profile, connector, cable, ambient, bundling, and converter fault data. |
|---|
| IMU1 | Bosch BMI088 pelvis IMU - proposed device | Exact package pins, decoupling, separate accel/gyro interfaces, PCB layout, clocking, and mechanical alignment are unresolved. |
|---|
| IMU2 | Bosch BMI088 torso IMU - proposed device | Exact package pins, decoupling, PCB layout, clocking, and mechanical alignment are unresolved. |
|---|
| ISO1 | Isolated safety-status input module | Input thresholds, isolation ratings, diagnostics, and exact terminals are unresolved. |
|---|
| JAC1 | AC inlet | Regional inlet, cord retention, ingress protection, and terminals are unresolved. |
|---|
| JCHG1 | Charge inlet | Connector, keying, touch protection, current, voltage, and presence-contact implementation are unresolved. |
|---|
| JHL1 | Left-leg harness bulkhead | Connector family, pin numbers, current per contact, keying, shielding, strain relief, and ingress rating are unresolved. Prohibit unreviewed full-conductor DYNAMIXEL links; release a VDD-isolating data harness and require continuity/no-backfeed tests. |
|---|
| JHR1 | Right-leg harness bulkhead | Connector family, pin numbers, current per contact, keying, shielding, strain relief, and ingress rating are unresolved. Prohibit unreviewed full-conductor DYNAMIXEL links; release a VDD-isolating data harness and require continuity/no-backfeed tests. |
|---|
| JSL1 | Left-foot sensor harness | Cable topology, connector, differential/analog routing, shielding, and pin map are unresolved. |
|---|
| JSR1 | Right-foot sensor harness | Cable topology, connector, differential/analog routing, shielding, and pin map are unresolved. |
|---|
| JT1 | HR-30 tethered ELV source inlet | 14.0-14.8 V current-limited 80 A-class source, connector, cable, PE/shield policy, and ratings are unresolved. |
|---|
| JUA1 | Upper-body bus A harness | Connector family, pin map, current capacity, contact count, keying, and strain relief are unresolved. Prohibit standard full-conductor TTL daisy cables; release a data-only harness and require continuity/no-backfeed tests. |
|---|
| JUB1 | Upper-body bus B harness | Connector family, pin map, current capacity, contact count, keying, and strain relief are unresolved. Prohibit standard full-conductor TTL daisy cables; release a data-only harness and require continuity/no-backfeed tests. |
|---|
| K1,K2 | Schneider LC1D25BD | Integral 21-22 NC mirror contact is used for EDM. Integral 13-14 NO is status only.,Second series contactor; same coordination restrictions as K1. |
|---|
| KB1 | Battery main source contactor | Coil voltage, DC make/break duty, inrush, mirror contact, suppression, and fault coordination are unresolved. |
|---|
| KH1 | HR-30 actuator-power contactor 1 | DC-rated 50 A-class architecture input only. Exact device, mirror-contact validity, coil, DC duty, inrush, and protection coordination are unresolved. |
|---|
| KH2 | HR-30 actuator-power contactor 2 | Second independent series contactor. Exact device and all coordination evidence are unresolved. |
|---|
| KP1 | Precharge relay | Contact voltage/current, coil drive, welded-contact detection, and timing are unresolved. |
|---|
| KWD1,KWH1 | Phoenix Contact PLC-RSC-24DC/21 | Supplemental normally-open watchdog permit; not safety-rated.,Supplemental watchdog permit only; not a safety relay. Normally-open 11-14 path is required for fail-safe permit behavior. |
|---|
| LCL1 | left foot 1 compression load cell 0-200 N | Exact load cell, bridge wiring, overload rating, cable, connector, calibration, and cross-axis behavior are unresolved. |
|---|
| LCL2 | left foot 2 compression load cell 0-200 N | Exact load cell, bridge wiring, overload rating, cable, connector, calibration, and cross-axis behavior are unresolved. |
|---|
| LCL3 | left foot 3 compression load cell 0-200 N | Exact load cell, bridge wiring, overload rating, cable, connector, calibration, and cross-axis behavior are unresolved. |
|---|
| LCL4 | left foot 4 compression load cell 0-200 N | Exact load cell, bridge wiring, overload rating, cable, connector, calibration, and cross-axis behavior are unresolved. |
|---|
| LCR1 | right foot 1 compression load cell 0-200 N | Exact load cell, bridge wiring, overload rating, cable, connector, calibration, and cross-axis behavior are unresolved. |
|---|
| LCR2 | right foot 2 compression load cell 0-200 N | Exact load cell, bridge wiring, overload rating, cable, connector, calibration, and cross-axis behavior are unresolved. |
|---|
| LCR3 | right foot 3 compression load cell 0-200 N | Exact load cell, bridge wiring, overload rating, cable, connector, calibration, and cross-axis behavior are unresolved. |
|---|
| LCR4 | right foot 4 compression load cell 0-200 N | Exact load cell, bridge wiring, overload rating, cable, connector, calibration, and cross-axis behavior are unresolved. |
|---|
| M1 | ROBOTIS XM540-W270-T shoulder, provisional ID 1 | TTL connector terminals are manufacturer-documented; mating housing/contact selection remains open. |
|---|
| M2 | ROBOTIS XM540-W270-T elbow, provisional ID 2 |
|---|
| M3 | ROBOTIS XM430-W350-T gripper, provisional ID 3 |
|---|
| M31 | ROBOTIS XM540-W270-T left shoulder pitch, provisional ID 31 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M32 | ROBOTIS XM540-W270-T left shoulder roll, provisional ID 32 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M33 | ROBOTIS XM540-W270-T left elbow, provisional ID 33 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M34 | ROBOTIS XM430-W350-T left wrist, provisional ID 34 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M35 | ROBOTIS XM430-W350-T left gripper, provisional ID 35 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M41 | ROBOTIS XM540-W270-T right shoulder pitch, provisional ID 41 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M42 | ROBOTIS XM540-W270-T right shoulder roll, provisional ID 42 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M43 | ROBOTIS XM540-W270-T right elbow, provisional ID 43 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M44 | ROBOTIS XM430-W350-T right wrist, provisional ID 44 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M45 | ROBOTIS XM430-W350-T right gripper, provisional ID 45 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M51 | ROBOTIS XM540-W270-T waist yaw, provisional ID 51 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M52 | ROBOTIS XC430-W240-T head pan, provisional ID 52 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| M53 | ROBOTIS XC430-W240-T head tilt, provisional ID 53 | Individual power branch; shared half-duplex TTL data chain. |
|---|
| ML1 | ROBOTIS XH540-W270-R left hip yaw, provisional ID 11 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| ML2 | ROBOTIS XH540-W270-R left hip roll, provisional ID 12 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| ML3 | ROBOTIS XH540-W270-R left hip pitch, provisional ID 13 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| ML4 | ROBOTIS XH540-W270-R left knee pitch, provisional ID 14 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| ML5 | ROBOTIS XH540-W270-R left ankle pitch, provisional ID 15 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| ML6 | ROBOTIS XH540-W270-R left ankle roll, provisional ID 16 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| MR1 | ROBOTIS XH540-W270-R right hip yaw, provisional ID 21 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| MR2 | ROBOTIS XH540-W270-R right hip roll, provisional ID 22 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| MR3 | ROBOTIS XH540-W270-R right hip pitch, provisional ID 23 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| MR4 | ROBOTIS XH540-W270-R right knee pitch, provisional ID 24 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| MR5 | ROBOTIS XH540-W270-R right ankle pitch, provisional ID 25 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| MR6 | ROBOTIS XH540-W270-R right ankle roll, provisional ID 26 | Power is star-injected by an individual fuse; only the differential data pair is intended to be bus-connected. Standard 4-pin cables are prohibited because they also carry VDD. |
|---|
| PETB1 | Protective-earth distribution block | Terminal block, bonding studs, conductor sizes, and continuity-test points are unresolved. |
|---|
| PI1 | Raspberry Pi 5 8GB high-level compute | Exact port allocation, GPIO interface board, grounding, and cable retention are unresolved. |
|---|
| PS1 | Mean Well LRS-350-12 | 12 V / 29 A candidate. Overload threshold is 110-140% rated power with hiccup recovery; 150% peak is allowed no more than 1 s. Cold-start inrush is 60 A typical at 115/230 VAC, with no published maximum or duration. No protection or conductor value is released. |
|---|
| PS2 | Mean Well HDR-30-24 | 24 V / 1.5 A candidate. Pulse-load calculation and bench validation remain open. |
|---|
| PS3 | Raspberry Pi 27 W USB-C supply | Regional order code, receptacle, and AC integration are unresolved; USB-C is a functional interface, not a pin-level cable drawing. |
|---|
| RD1 | DC-link discharge path | Discharge resistance, power, touch-safe voltage time, and thermal mounting are unresolved. |
|---|
| RP1 | Precharge resistor | Resistance, pulse energy, power, tolerance, mounting, temperature, and discharge interval require measured load capacitance. |
|---|
| RT1 | STM32H743-class deterministic motion controller | Exact controller board, transceivers, pin map, isolation, and power integrity are unresolved. |
|---|
| RTL1 | left leg near-end RS-485 termination | Fit only at the verified controller-side physical end. Resistance and placement require cable-impedance and transceiver review. |
|---|
| RTL2 | left leg far-end RS-485 termination | Fit only at the verified far physical end. No intermediate termination is permitted. |
|---|
| RTR1 | right leg near-end RS-485 termination | Fit only at the verified controller-side physical end. Resistance and placement require cable-impedance and transceiver review. |
|---|
| RTR2 | right leg far-end RS-485 termination | Fit only at the verified far physical end. No intermediate termination is permitted. |
|---|
| S0 | Dual-NC positively-opening E-stop | IDEC XW dual-NC is a family candidate only. Freeze the exact complete order code, operator/reset/contact/cover/environment details, attach the exact bottom-view drawing, and continuity-test the received unit before replacing TBD terminals. |
|---|
| S1 | Momentary NO reset pushbutton | Exact normally-open contact and terminal identifiers are unresolved. Locate outside swept envelope. |
|---|
| SD1 | Accessible DC service disconnect | Exact DC rating, poles, breaking capacity, touch protection, and lockout method are unresolved. |
|---|
| SH0 | HR-30 dual-NC positively-opening E-stop | IDEC XW dual-NC is a family candidate only. Freeze the exact complete order code, operator/reset/contact/cover/environment details, attach the exact bottom-view drawing, and continuity-test the received unit before replacing TBD terminals. |
|---|
| SH1 | HR-30 momentary NO reset pushbutton | Exact normally-open contact, terminal identifiers, location, and environmental rating are unresolved. |
|---|
| SHLD1 | RS-485 shield-drain termination assembly | Single-ended, capacitive, or direct chassis termination policy requires EMC testing; do not create an unintended DC 0 V/PE bond. |
|---|
| SK1 | K1 DC-coil suppression network | Select per Pilz and Schneider instructions. Exact device, polarity, energy rating, fault behavior, and effect on dropout/stopping time require review and test. |
|---|
| SK2 | K2 DC-coil suppression network | Select per Pilz and Schneider instructions. Exact device, polarity, energy rating, fault behavior, and effect on dropout/stopping time require review and test. |
|---|
| SKH1 | KH1 DC-coil suppression network | Select per Pilz and chosen contactor instructions. Exact device, polarity, energy rating, fault behavior, and effect on dropout/stopping time require review and test. |
|---|
| SKH2 | KH2 DC-coil suppression network | Select per Pilz and chosen contactor instructions. Exact device, polarity, energy rating, fault behavior, and effect on dropout/stopping time require review and test. |
|---|
| SP1 | Removable single-point DC 0 V / PE bond assembly | DEFAULT OPEN. Populate only the single reviewed link; do not bridge all return domains by assumption. |
|---|
| SR1,SRH1 | Pilz PNOZ s4 24 VDC, 750104 - PROPOSED CHANGE | Select and seal 'with detection of shorts across contacts / monitored start falling edge' with supply off. 750104 falling-edge wait 250 ms and minimum start pulse 100 ms. Qualified review and physical validation remain required. |
|---|
| SRCSEL1 | Mutually exclusive tether/battery source selector | Break-before-make or variant-keyed implementation is unresolved. Sources must never be electrically paralleled. |
|---|
| TB24 | 24 V safety-control terminal block | This block is downstream of PS2 only; it has no electrical connection to TBAC1 beyond the power-supply isolation boundary. |
|---|
| TBAC1 | Guarded mains terminal block | No exposed mains terminal may be accessible without a tool. Terminal family, jumpers, covers, and ratings are unresolved. |
|---|
| TBHR30 | HR-30 actuator terminal block | Terminal selection, branch allocation, current sharing, barriers, and conductor sizing are unresolved. |
|---|
| TBV0 | HR-V0 actuator terminal block | Terminal selection and conductor allocation are unresolved. No terminal on TBV0 feeds HR-30. |
|---|
| TLM1 | Independent battery telemetry interface | Isolation, voltage measurement, current sensing, accuracy, fault behavior, and exact interface are unresolved. |
|---|
| TP1 | Commissioning test-point and lockout panel | Finger-safe test points, covers, labels, voltage categories, and lockout procedures are unresolved. |
|---|
| WD1 | Independent HR-V0 watchdog controller | Exact RP2040-class board, brownout response, firmware integrity, and startup state are unresolved. |
|---|
| WDH1 | Independent HR-30 watchdog controller | Separate variant hardware. Exact controller, startup state, brownout, and fault latch are unresolved. |
|---|
| XCVRL1 | left leg isolated RS-485 transceiver | Exact transceiver, isolation, fail-safe bias, common-mode range, ESD protection, connector, and controller pins are unresolved. |
|---|
| XCVRR1 | right leg isolated RS-485 transceiver | Exact transceiver, isolation, fail-safe bias, common-mode range, ESD protection, connector, and controller pins are unresolved. |
|---|